Measuring Gas in Reactions
Overview
Learning objectives
- Describe how to measure the gas given off in a reaction with a gas syringe, by mass loss and by collecting over water.
- Choose the right method for a gas, using its solubility and density.
- Spot the sources of error in each method and suggest improvements.
- Calculate a mean rate from results, with the correct units.
- HT Draw a tangent to a curve and use its gradient to find the rate at a given time.
Why measure a gas?
When a reaction gives off a gas, the amount of gas made tells you how far the reaction has gone. Taking a reading every 10 seconds lets you plot a graph and work out the rate of reaction:
The three setups
Press Play to start the reaction, or drag the time slider to any moment. Tick Live graph to plot the results as they come in, and Tangent to see the rate at that instant.
Method 1
Method 2
Mass loss: balance and cotton wool
Method 3
Downward displacement of water
Comparing the three methods
Each method measures the same thing, how much gas has been made, but each one suits some gases better than others.
| Method | What you measure | Advantages | Disadvantages & limitations | Best for |
|---|---|---|---|---|
| Gas syringe | Volume of gas (cm³) |
|
|
CO2, H2, O2; the most versatile |
| Mass loss | Mass of the flask and contents (g) |
|
|
Dense gases: CO2 |
| Over water | Volume of gas (cm³) |
|
|
Insoluble gases: H2, O2 |
Which method for which gas?
| Gas | Solubility in water | Density (Mr) | Good choices |
|---|---|---|---|
| Hydrogen, H2 | Insoluble | Very light (2) | Syringe or over water. Not mass loss. |
| Oxygen, O2 | Almost insoluble | Medium (32) | Syringe or over water |
| Carbon dioxide, CO2 | Slightly soluble | Heavy (44) | Syringe or mass loss. Over water reads low. |
Two questions to ask
1. Does the gas dissolve in water? If it does, collecting it over water loses some of it, so use a gas syringe.
2. Is the gas heavy enough to weigh? A mole of H2 weighs only 2 g, so the mass change is too small to measure accurately. A mole of CO2 weighs 44 g, which a balance picks up easily.
Whichever method you use, the shape of the graph is the same: steep at first, then levelling off when a reactant is used up.
Revision notes
1Gas syringe
Equipment
- Conical flask with a one-hole bung and delivery tube
- Gas syringe (100 cm³), clamped
- Stopwatch
- Measuring cylinder for the acid
- Magnesium ribbon and dilute hydrochloric acid
Method
- Check the syringe plunger is pushed fully in and reads 0 cm³.
- Measure 50 cm³ of acid into the flask.
- Add the magnesium, put the bung in straight away and start the stopwatch.
- Record the volume on the syringe every 10 s until it stops changing.
- Repeat with a different concentration of acid, keeping everything else the same.
Sources of error and improvements
| Problem | Effect | Improvement |
|---|---|---|
| Gas escapes before the bung is in | Volumes too low | Put the acid in a small tube inside the flask and tip it over after the bung is in |
| Plunger sticks | Volume jumps instead of rising smoothly | Check the syringe moves freely before starting |
| Reaction too fast | Syringe fills before the end | Use less magnesium or more dilute acid |
| Leaky bung or joints | Volumes too low | Check the seals are airtight |
2Mass loss
Equipment
- Conical flask and cotton wool plug
- Digital balance reading to 0.01 g
- Stopwatch
- Marble chips (calcium carbonate) and dilute hydrochloric acid
Method
- Put the acid in the flask and the chips beside it on the balance, with the cotton wool.
- Add the chips to the acid, plug the neck with cotton wool and start the stopwatch.
- Record the mass every 10 s until it stops falling.
- Work out the mass lost at each time: starting mass − reading.
Sources of error and improvements
| Problem | Effect | Improvement |
|---|---|---|
| Acid spray escapes from the flask | Mass loss too big | Use a cotton wool plug |
| Draughts push on the pan | Readings drift | Use a draught shield; close windows |
| Gas is very light (H2) | Change too small to measure | Use a gas syringe instead |
| Some CO2 stays dissolved in the acid | Mass loss slightly low at first | Swirl the flask the same way each time |
3Downward displacement of water
Equipment
- Conical flask, bung and delivery tube
- Trough (or large bowl) of water
- 100 cm³ measuring cylinder, clamped upside down
- Stopwatch
- Hydrogen peroxide solution and manganese(IV) oxide catalyst
Method
- Fill the measuring cylinder completely with water, cover the top and turn it upside down in the trough.
- Clamp it with the open end under the water and place the end of the delivery tube underneath.
- Add the catalyst, put the bung in and start the stopwatch.
- Record the volume of gas every 10 s. Read at the water level; the scale runs downwards.
Sources of error and improvements
| Problem | Effect | Improvement |
|---|---|---|
| Gas dissolves in the water | Volumes too low | Use a gas syringe for soluble gases such as CO2 |
| Air left in the cylinder at the start | Volumes too high, or start reading not 0 | Fill completely; record the starting level |
| Reading the upside-down scale | Misread volumes | Read at eye level at the bottom of the meniscus |
| Water sucked back into the flask | Experiment ruined | Remove the delivery tube from the water before anything cools |
“The gas displaces the water downwards” describes what happens in the cylinder. Don't confuse it with downward delivery, a different way of collecting dense gases in a gas jar.
4Calculating rate from results
Mean rate
The mean (average) rate over a time interval is the change in quantity divided by the time taken:
rate = ΔVolumeΔTime (cm³/s) or rate = ΔMassΔTime (g/s)
A gas syringe reads 0 cm³ at the start and 36 cm³ after 30 s. Mean rate = 36 ÷ 30 = 1.2 cm³/s.
A flask on a balance falls from 125.40 g to 124.80 g in 60 s. Mass lost = 0.60 g, so mean rate = 0.60 ÷ 60 = 0.010 g/s.
Units always come from the quantity divided by the time: cm³/s, g/s, and at Higher Tier mol/s. Rate can also be given per minute if time was measured in minutes.
Reading the graph
- The steeper the line, the faster the reaction.
- The curve is steepest at the start, when the reactants are most concentrated.
- It gets less steep as reactants are used up, and goes flat when the reaction stops.
- The height of the flat part is the total amount of gas. It depends on the amount of the limiting reactant, not on the rate.
Rate at a particular time: tangents HT
- Find the point on the curve at the time you want.
- Place a ruler so it just touches the curve there, without cutting across it, and draw the tangent.
- Make a large right-angled triangle under the tangent.
- Gradient = change in ychange in x = rate at that time.
From the tangent at 20 s: Δy = 68 − 12 = 56 cm³ and Δx = 40 − 0 = 40 s. Rate = 56 ÷ 40 = 1.4 cm³/s.
Reading the gradient from a tiny triangle: draw it as big as the tangent allows.
Using the curve's own value at that time (for example 40 cm³ ÷ 20 s). That gives the mean rate from the start, not the rate at 20 s.
Worksheet
ACompare the methods
Complete the table.
| Method | What is measured, and in what unit? | One advantage | One limitation |
|---|---|---|---|
| Gas syringe | |||
| Mass loss | |||
| Over water |
BChoose a method
For each reaction, name the best method and give a reason.
(a) Zinc + sulfuric acid → zinc sulfate + hydrogen
(b) Calcium carbonate + hydrochloric acid → calcium chloride + water + carbon dioxide
(c) A student collects carbon dioxide over water and a gas syringe in two identical experiments. Which gives the larger final volume? Explain why.
CPlot and analyse
A student decomposed hydrogen peroxide with a catalyst and collected the oxygen in a gas syringe.
| Time (s) | 0 | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 |
|---|---|---|---|---|---|---|---|---|---|
| Volume (cm³) | 0 | 20 | 33 | 42 | 48 | 52 | 55 | 56 | 58 |
(a) Plot the results on the grid. Label the axes, choose a sensible scale and draw a smooth curve of best fit.
(b) Calculate the mean rate of reaction over the first 20 s. Give the unit.
(c) HT Draw a tangent to your curve at 30 s and use it to find the rate at 30 s.
DSpot the error
A student added the acid, then took 5 s to put the bung in and start the stopwatch. Explain how this affects the results and how to prevent it.
Worksheet answers (teacher copy)
A. Syringe: volume, cm³; any gas / accurate; max 100 cm³ / plunger sticks. Mass loss: mass, g; precise balance / simple; no good for light gases (H2) / gas released into room. Over water: volume, cm³; cheap / see gas collect; soluble gases dissolve / upside-down scale.
B. (a) Gas syringe or over water: hydrogen is insoluble but too light for mass loss. (b) Mass loss or gas syringe: CO2 is dense (Mr 44) but slightly soluble in water. (c) The syringe: some CO2 dissolves in the water, so less is collected over water.
C. (b) 33 ÷ 20 = 1.65 ≈ 1.7 cm³/s. (c) About 0.7 cm³/s (accept 0.5–0.9), from a large triangle on a correctly drawn tangent.
D. Gas made in the first 5 s is lost / not measured, so every volume is too low (a systematic error) and the early rate looks slower. Tip the reactants together after the bung is in, e.g. acid in a small tube inside the flask, or start the stopwatch as the reactants meet.
Check for understanding
Six quick questions. Pick an answer to see whether you are right and why.
Exam-style questions
Write your answer in each box, then open the mark scheme and tick every point you got. Your score adds up at the top.
Answer all questions in the spaces provided. Total: 29 marks. HT marks a Higher Tier part.